Two City of Clinton engineering reports document the former YMCA at 274 5th Avenue South / 480 South 3rd Street after closure: Select Structural Engineering (October 20, 2022) found the women's locker-room building not salvageable — a failed roof, significant moisture, steel a complete loss, and mold and potential asbestos a significant risk — and the C2/C3 locker rooms 'very moist' with 'a lot of mold'; IMEG (October 28, 2024) called the pool/basketball/locker-room addition an unsafe structure, with mold, mildew, and mushrooms growing on the floor from the leaking roof, and recommended removal. A closed facility, documented at the end of its life — not a currently operating club.
Clinton, Iowa, United States — reports October 20, 2022 and October 28, 2024 Documented
Former YMCA — Clinton, IA (274 5th Ave S; the city’s brownfield records use 480 S 3rd St, Clinton, IA 52732) is documented here from two engineering reports published by the City of Clinton: Select Structural Engineering’s structural report of October 20, 2022, and IMEG Consultants Corp.’s report on the pool building complex of October 28, 2024 (IMEG Project #23003451.00); both were cataloged in this site’s Weekly Sweep #1 (October 19, 2026) and both were fetched in full for this page. One scope statement before the record: this facility was already closed when the engineers walked it — the YMCA building’s later life in the city’s records is as a brownfield cleanup and redevelopment site. This page documents a wet athletic building at the end of its life, not a club anyone can join today, and nothing here describes a currently operating YMCA program in Clinton.
- The 2022 report — Building B1, the women’s locker-room building: not salvageable. Building B1 housed the women’s locker room, the boiler room, and second-story offices. Select Structural Engineering’s opinion, verbatim in substance: the building is not salvageable; its roof was not successful at keeping water out; the level of moisture in the building envelope was/is significant; the steel structural framing is a complete loss that no licensed structural engineer would certify — in addition to the mold and potential asbestos, which presents a significant risk to occupants including contractors who would need to work inside.
- The 2022 report — Buildings C2/C3, the men’s side: “a lot of mold.” C2/C3 housed racquetball courts, a second pool, the men’s locker room, a basketball court, offices, a running track, and the HVAC system. The open-web floor system did not hold up well in the moist conditions and should be planned for replacement, with significant rust to the joists and steel skeleton. And the sentence this page exists to print, in the engineers’ own words: “the interior of the locker rooms is very moist and there is a lot of mold in this area” — flagged by the engineers themselves as a non-structural issue requiring a specialist to figure out how/if it can be abated. Building A, the original building, by contrast, was found salvageable — the report attributes that directly to the lack of water in the structure: where the water never got in, the building survived.
- The engineers’ own fence, carried here. Select Structural states its report focuses on structure and is not meant to provide instruction for mold, asbestos, or other non-structural deficiencies, that noting mold and asbestos does not make it an abatement specialist, and that the report is a bird’s-eye view, not an exhaustive list. No species was identified, no sampling is reported, and none is claimed here.
- The 2024 report — the addition is an unsafe structure, with mushrooms on the floor. IMEG’s October 28, 2024 opinion on the pool / basketball court / locker-room addition west of the original building: it is an unsafe structure under International Building Code Section 116.1. The basketball floor had buckled and warped in a way that may destabilize the walls; mold/mildew and mushrooms were growing on the floor inside the building; steel beam framing was rusted and ceiling panels had collapsed — all due to the leaking roof structure over the years. The pavement beside the complex was heavily cracked and appeared settled or undermined, perhaps by a downspout discharging under it. IMEG’s recommendation: the building be removed in accordance with the IBC; it is unsafe for contractors to enter for removal of selective materials; and because the building contains asbestos, demolition should follow the applicable abatement requirements.
What this page does not hold, stated as plainly as the record allows: both reports are post-closure condition reports — they document what years of roof failure did to a vacant building, and they do not establish what the locker rooms were like while the YMCA operated, when the roof first failed, or whether any member was ever exposed to the growth the engineers found. No illness is recorded in either report and none is claimed here. The 2024 report’s address line is the pool complex on 5th Avenue South; the city’s environmental records place the former YMCA parcel at 480 South 3rd Street — the same complex, two address conventions, printed as the sources print them.
Why this one matters
Every other Gym Watch page on this shelf argues from a record made while a building was in use — an inspection, a complaint, a review. This one argues from the autopsy. Two independent engineering firms, two years apart, walked the same wet complex and converged on the same mechanism this site’s Zero-Mold Sauna Blueprint is built against: a roof that leaks for years does not produce a stain; it produces a building whose locker rooms grow mushrooms, whose steel is a complete loss, and whose only remaining professional recommendation is removal. The 2022 report even runs the control experiment inside its own pages — the original building, kept dry, is salvageable; the additions the water reached are not. Moisture is not a cosmetic category. Given enough unattended years, it is the difference between a building and a demolition. The questions this page puts on the record are for the public file, not any operator: what did the city’s cleanup and demolition record ultimately show, and was the growth abated before any demolition released it? Any documented answer will be carried here.
Trying to leave this gym?
This page is a closed-facility record, not a membership file. The cancellation and billing record for gyms lives in The Gym Trap — start there, and put every cancellation in writing with a date you can prove.
If this happened to you
Swam, lifted, or worked in a building officials later condemned — or maintain one whose roof has been “next year’s budget” for years? File a report with the dates and the documents: engineering and inspection reports are public records, and a dated report is how a leaking roof stops being an anecdote.
Trying to leave this gym? Joining took minutes online; leaving is its own fight — no cancel button, voicemail walls, a billing company, and a collector. That pipeline is documented step by step in The Gym Trap. In Florida, the exit is written into state law: How to Cancel a Gym in Florida (Fla. Stat. §501.017) — including the disability cancellation and the written-notice rule that terminates your obligation to any collector the gym handed your contract to.